Module makes electric vehicle temperature measurements safer

M-Thermo 2 HV thermocouple module from Ipetronik

A thermocouple module for K-type sensors has been introduced by Ipetronik to meet the requirements for protecting specialised staff in high-voltage measurement systems in the testing departments of hybrid and electric vehicle manufacturers.

The M-Thermo 2 HV provides versatility by having four inputs for safe temperature measurement on high voltage potentials. It can be integrated into M2 systems and has quick configuration and data analysis in IPEmotion and the company’s data loggers. Personal protection is guaranteed by certified high-voltage thermocouples and cables.

The enclosure measures 106 by 73 by 60mm and meets protection class IP65; it is for direct application in the engine compartment, operates in a temperature range of -40 to +105˚C, and requires 6 to 36V DC for the power supply. Power consumption is typically under 0.9W.

The temperature measuring range goes from -60 to +1370˚C and is digitalised per channel with a 24bit analogue-digital converter. The cold junction compensation takes place on the sockets of measurement inputs using RTDs (PT100 elements). The adjustment of the A-D measuring chain is performed with each measurement acquisition.

To increase accuracy, the sensor characteristic curve is numerically interpolated through an intern compensation algorithm. Accuracy at +25˚C ambient temperature is specified with ±0.035% of the full temperature measuring range.

Input voltage protection is ±50V DC indefinitely and ±200V DC short term. It supports channel sample rates of 1, 2, 5 and 10min as well as 1, 2, 5, 10, 20, 50 and 100Hz. In Cat I applications the permitted input voltage is 846V DC, in Cat II it is 500V AC at 50Hz. All the measurement inputs, Can bus, power supply and enclosure are galvanically isolated up to an isolation voltage of 846V DC. Status LEDs on each measurement input inform about correct channel allocation or sensor breaks in measurement operations.

The data output occurs via Can bus in accordance with ISO 11898-2 at up to 1Mbit/s. The measuring data have a 2byte (16bit) resolution with or without sign.

The module is available with two connector types – Lemo or thermosensor sockets. A separate HV safety socket is available for each input. A fixing technique provides a combination of modules without any tools.

“New drive concepts of electric and hybrid vehicles have very high requirements on riskless measurements in HV systems,” said Harry Stoerzer, Ipetronik’s director of application and support. “The certified module is especially suitable for safe measurements in high-voltage potentials in mobile testing.”

www.ipetronik.com

Recommend to Colleagues: